| Housing |
Cast Aluminum w/ Powder Coat Finish |
| Output |
Analog |
| Operating Voltage |
230 VAC, 50/60 Hz |
| Cable Type |
1/16" Nylon jacketed |
| Enclosure |
NEMA 4X, IP66 |
| Environment |
Ordinary locations CSA us/c |
| Weight |
35 lbs |
| Accuracy |
± 0.25% of distance reading |
| Mounting |
Freeze-Resistant "K" flange, 8"dia w/ 7" bolt circle |
| Input Signal |
Sound (Pulse, Analog): Vhi - 98-265 VAC / VDC, 9.5 K ohm input, isolated Vlo - 20-55 VAC /VDC, 2.0 K ohm input, isolated
Lockout (All): Vhi - 98-265 VAC / VDC, 9.5 K ohm input, isolated Vlo - 20-55 VAC / VDC, 2.0 K ohm input, isolated |
| Conduit Entry |
(2) 3/4 NPT |
| Output Signal |
4-20 mA, reversible to 20-4 mA, isolated, 500 Ohms maximum loop resistance, Relay Output - 5A at 250 VAC max, isolated, dry contact |
| Pollution Degree |
4, Suitable for indoor/outdoor use |
| Power Consumption |
6 VA continuous, 50 VA intermittent |
| Ambient Operating Temp |
-40 to 150° F |